top of page
Fallis PH wall solid stud external view.
Fallis PH wall solid stud internal view.
Fallis PH wall 50%.jpg

Solid stud option U-value 0.15 W/m2K

​

External view

1. 45x220mm C16 Vac Vac treated timber stud @ 600mm crs.

2. Warmcel insulation.

3. Elka Strong Board (diffusion open).

4. Siga Majcoat breather membrane.

5. Siga Wigluv tape (windtight layer).

6. Radon Barrier.

​

​

Internal view

7. Siga Majpell 5 (airtight layer).

8. 22x45mm vertical batten.

9. 50mm Rockwool Flexi.

10. 45x45mm horizontal batten.

11. Sand cement screed.

12. Floor insulation.

 

Timber frame construction diagram twin s
Timber frame construction diagram twin s
Fallis PH wall 50%.jpg

Twin stud option U-value 0.10 W/m2K

​

External view

1. 45x300mm Twin stud C16 Vac Vac treated timber stud @ 600mm crs.

2. Warmcel insulation.

3. Elka Strong Board (diffusion open).

4. Siga Majcoat breather membrane.

5. 45x45mm vertical batten.

6. Timber cladding (external finish to clients specification)

7. Siga Wigluv tape (windtight layer).

8. Quinnlite block (B7).

9. EPS insulation.

​

​

Internal view

10. Durelis VapourBlock

11. 22x45mm vertical batten.

12. 45x45mm horizontal batten.

13. Sand cement screed.

14. EPS insulation.

​

 

Timber frame construction diagram I Beam
Timber frame construction diagram I Beam

External view

​

​

​

​

Internal view

​

​

 

Fallis PH wall 50%.jpg

I beam stud option U-value 0.10 W/m2K

​

1. I Beam stud timber stud @ 600mm crs.

2. Warmcel insulation.

3. Elka Strong Board (diffusion open).

4. Siga Majcoat breather membrane.

5. Siga Rissan tape.

6. Durelis VapourBlock

​

​

​

bottom of page